addrbookFor publishers
← The evidence ledger

Evidence row 1226247

Observed , by probe.mcp/1.

Kind
mcp.tools
About
endpoint 95eddd47-f487-4191-a5bd-3756bb90e52d
Recorded
Previous row
None: the first of its kind about this subject
Body SHA-256
e3f2a1d472164d0898bd36b84941a9c5af2bc789b1dda97daec70b4ab68e334e
Leaf
0x3ae8fcc89152ca6192eb10a928a0761b1671e65a40877220ff086bb93a42b39d

What was observed

{
  "count": 8,
  "tools": [
    {
      "description": "[PRO] Performs numerical technical calculations for construction trades with code-compliant results. Use this tool when a specific measurement, size, rating, or capacity needs to be calculated — not just checked for compliance. Returns the calculated value with units, the method or formula used, relevant derating or correction factors, and the code reference that governs the calculation. Supports: cable/conductor sizing (mm2 or AWG), voltage drop (%), pipe sizing (mm or inches), HVAC duct sizing (CFM/L/s), heat load calculations, load current calculations, and more. Example inputs: 'Cable size for 32A circuit, 25m run, 240V single phase, clipped direct', 'Pipe size for 40 fixture units copper hot water supply', 'Duct size for 1200 CFM round duct'.",
      "inputSchema": {
        "properties": {
          "api_key": {
            "description": "Pro API key required. Get at https://rickyfarmer.gumroad.com/l/Legis-LinkPro",
            "type": "string"
          },
          "calculation": {
            "description": "Describe the calculation needed with all relevant parameters. Include: load/flow value, distance/length, voltage/pressure, installation method, ambient conditions. Example: 'Cable size for 45A, 30m run, 240V, single phase, in conduit, 35 degrees ambient'.",
            "type": "string"
          },
          "region": {
            "description": "Use the state, province or country where the user works; if they have not said, ask them - never assume NSW or Australia. Jurisdiction. Affects which standard and units apply (e.g. mm2 for AU/UK, AWG for USA).",
            "type": "string"
          },
          "role": {
            "default": "Qualified Tradesperson",
            "description": "User role. Affects detail level of the output.",
            "enum": [
              "Apprentice / Trainee",
              "Qualified Tradesperson",
              "Supervisor / Foreman",
              "Manager / Executive"
            ],
            "type": "string"
          },
          "trade": {
            "description": "The trade for this calculation. Determines the applicable standard and units.",
            "enum": [
              "Electrical",
              "Plumbing",
              "HVAC",
              "Welding",
              "Carpentry",
              "Fire protection",
              "Concrete",
              "Roofing",
              "Gas fitting",
              "Solar / Battery"
            ],
            "type": "string"
          }
        },
        "required": [
          "trade",
          "region",
          "calculation"
        ],
        "type": "object"
      },
      "name": "calculate_technical_spec"
    },
    {
      "description": "Answers construction trade compliance questions with exact code references and clause citations. Use this tool when a tradesperson or engineer asks whether a specific installation, practice, or configuration is compliant with local regulations. Returns a COMPLIANT, NON_COMPLIANT, or REQUIRES_VERIFICATION status with the precise standard (e.g. AS/NZS 3000:2018 Clause 3.2.4) and any critical caveats. Covers electrical, plumbing, HVAC, welding, carpentry, roofing, gas fitting, solar, fire protection, and concrete trades across Australia, UK, USA, Canada, and EU. Do NOT use this tool for numerical calculations (use calculate_technical_spec instead) or for generating safety checklists or RAMS documents.",
      "inputSchema": {
        "properties": {
          "api_key": {
            "description": "Legis-Link API key. Optional: leave empty for the free tier (50 requests/day); Pro users paste their ll_p_ key. Get a free key at https://legis-link.com",
            "type": "string"
          },
          "question": {
            "description": "The compliance question in plain English. Be specific: include voltages, distances, materials, or load values where relevant. Example: 'Is 2.5mm2 TPS cable compliant for a 20A circuit in a wall cavity?'",
            "type": "string"
          },
          "region": {
            "description": "Use the state, province or country where the user works; if they have not said, ask them - never assume NSW or Australia. Jurisdiction for the compliance check. Examples: 'NSW', 'England', 'Texas', 'Ontario', 'Germany'. Determines which standard applies.",
            "type": "string"
          },
          "role": {
            "default": "Qualified Tradesperson",
            "description": "The role of the person asking. Affects the depth and terminology of the answer.",
            "enum": [
              "Apprentice / Trainee",
              "Qualified Tradesperson",
              "Supervisor / Foreman",
              "Manager / Executive"
            ],
            "type": "string"
          },
          "trade": {
            "description": "The construction trade relevant to the question. Must match a supported trade exactly.",
            "enum": [
              "Electrical",
              "Plumbing",
              "HVAC",
              "Welding",
              "Carpentry",
              "Fire protection",
              "Concrete",
              "Roofing",
              "Gas fitting",
              "Solar / Battery"
            ],
            "type": "string"
          }
        },
        "required": [
          "trade",
          "region",
          "question"
        ],
        "type": "object"
      },
      "name": "check_compliance"
    },
    {
      "description": "[PRO] Generates a complete Risk Assessment and Method Statement (RAMS) document — called a Job Hazard Analysis (JHA) in the USA or Safe Work Method Statement (SWMS) in Australia. Use this tool when a foreman or PM needs a formal safety document before a high-risk task. Output includes: Section 1 — Hazard Register (tabular, with severity/likelihood/risk rating/controls/regulations), Section 2 — Method Statement (numbered sequential steps), Section 3 — Required Qualifications and Certifications. The document is formatted for printing or inclusion in a site safety file. This tool produces a longer output than other tools — expect 800-1500 words. Example tasks: 'Electrical switchboard installation in commercial building NSW', 'Gas line installation in residential kitchen UK', 'Roof framing timber frame residential NSW'.",
      "inputSchema": {
        "properties": {
          "api_key": {
            "description": "Pro API key required.",
            "type": "string"
          },
          "company_name": {
            "description": "Optional. Company name to include in the document header.",
            "type": "string"
          },
          "region": {
            "description": "Use the state, province or country where the user works; if they have not said, ask them - never assume NSW or Australia. Jurisdiction. Determines applicable WHS/CDM/OSHA legislation cited in the document.",
            "type": "string"
          },
          "role": {
            "default": "Foreman",
            "description": "Role of the person generating the RAMS. Foreman or PM recommended.",
            "enum": [
              "Apprentice / Trainee",
              "Qualified Tradesperson",
              "Supervisor / Foreman",
              "Manager / Executive"
            ],
            "type": "string"
          },
          "site_address": {
            "description": "Optional. Site address to include in the document header.",
            "type": "string"
          },
          "task": {
            "description": "Full description of the task requiring the RAMS. Include: what work, where, at what height or voltage, any confined space, any hot work. The more detail, the more accurate the hazard register.",
            "type": "string"
          },
          "trade": {
            "description": "The trade performing the work.",
            "enum": [
              "Electrical",
              "Plumbing",
              "HVAC",
              "Welding",
              "Carpentry",
              "Fire protection",
              "Concrete",
              "Roofing",
              "Gas fitting",
              "Solar / Battery"
            ],
            "type": "string"
          }
        },
        "required": [
          "trade",
          "region",
          "task"
        ],
        "type": "object"
      },
      "name": "generate_rams"
    },
    {
      "description": "[PRO] Generates a numbered safety checklist for a specific construction task with PPE requirements, hazard controls, and regulatory citations for each item. Use this tool when a foreman or safety officer needs a task-specific checklist before work begins. Each checklist item includes: the safety requirement, the specific control measure, and the regulation or standard that mandates it (e.g. WHS Act 2011, CDM 2015, OSHA 29 CFR 1926). Do NOT use this tool to generate a full RAMS document — use generate_rams for that. Example tasks: 'working at height on a residential roof', 'hot work near fuel lines', 'isolating and working on a 415V switchboard'.",
      "inputSchema": {
        "properties": {
          "api_key": {
            "description": "Pro API key required.",
            "type": "string"
          },
          "region": {
            "description": "Use the state, province or country where the user works; if they have not said, ask them - never assume NSW or Australia. Jurisdiction. Determines which WHS/HSE regulations and codes of practice apply.",
            "type": "string"
          },
          "role": {
            "default": "Qualified Tradesperson",
            "description": "Role of the person who will use the checklist.",
            "enum": [
              "Apprentice / Trainee",
              "Qualified Tradesperson",
              "Supervisor / Foreman",
              "Manager / Executive"
            ],
            "type": "string"
          },
          "task": {
            "description": "Specific task description. Be precise about the activity, location, and any known hazards. Example: 'Installing 415V switchboard in an occupied commercial building, working at 3m height'.",
            "type": "string"
          },
          "trade": {
            "description": "The trade performing the task.",
            "enum": [
              "Electrical",
              "Plumbing",
              "HVAC",
              "Welding",
              "Carpentry",
              "Fire protection",
              "Concrete",
              "Roofing",
              "Gas fitting",
              "Solar / Battery"
            ],
            "type": "string"
          }
        },
        "required": [
          "trade",
          "region",
          "task"
        ],
        "type": "object"
      },
      "name": "generate_safety_checklist"
    },
    {
      "description": "Retrieves specific code sections, standards, and regulatory references for a construction trade topic. Use this tool when you need to cite the exact standard document, clause number, table reference, or regulatory instrument — without asking a yes/no compliance question. Returns the standard name, edition year, specific clause or table, and a plain-English summary of what that clause requires. Useful for pre-populating compliance documents, RAMS, or certificates. Examples: 'AS/NZS 3008 cable sizing tables', 'CDM 2015 notification thresholds', 'NEC Article 210 branch circuits'.",
      "inputSchema": {
        "properties": {
          "api_key": {
            "description": "Legis-Link API key. Optional: leave empty for the free tier (50 requests/day); Pro users paste their ll_p_ key.",
            "type": "string"
          },
          "region": {
            "description": "Use the state, province or country where the user works; if they have not said, ask them - never assume NSW or Australia. Jurisdiction. Determines which edition of the standard applies. Examples: 'NSW', 'England', 'California'.",
            "type": "string"
          },
          "topic": {
            "description": "The specific topic or subject to look up. Example: 'cable sizing for final sub-circuits', 'maximum water heater temperature', 'roof pitch minimums'.",
            "type": "string"
          },
          "trade": {
            "description": "The construction trade for which you need a code reference.",
            "enum": [
              "Electrical",
              "Plumbing",
              "HVAC",
              "Welding",
              "Carpentry",
              "Fire protection",
              "Concrete",
              "Roofing",
              "Gas fitting",
              "Solar / Battery"
            ],
            "type": "string"
          }
        },
        "required": [
          "trade",
          "region",
          "topic"
        ],
        "type": "object"
      },
      "name": "get_code_reference"
    },
    {
      "description": "[PRO] Returns all mandatory inspection hold points, sign-off authorities, certificates to be issued, and notification requirements for a construction installation in a specific jurisdiction. Use this tool when a foreman or PM needs to know: who must inspect, at what stage work must stop, what certificate is issued, and which regulation mandates the inspection. Prevents costly rework caused by covering work before mandatory inspection. Returns a numbered list of inspection stages with: inspector role/authority, certificate type and form number, regulatory reference, and notification timing. Example installations: 'residential electrical installation NSW', 'timber frame residential build NSW', 'gas fitting domestic kitchen UK'.",
      "inputSchema": {
        "properties": {
          "api_key": {
            "description": "Pro API key required.",
            "type": "string"
          },
          "installation": {
            "description": "Description of the installation requiring inspection. Be specific about scope. Example: 'new 3-bedroom residential electrical installation including switchboard, circuits, and solar inverter connection, NSW'.",
            "type": "string"
          },
          "region": {
            "description": "Use the state, province or country where the user works; if they have not said, ask them - never assume NSW or Australia. Jurisdiction. Inspection authorities and certificate types vary significantly by region.",
            "type": "string"
          },
          "role": {
            "default": "Qualified Tradesperson",
            "description": "Role of the person requesting the inspection requirements.",
            "enum": [
              "Apprentice / Trainee",
              "Qualified Tradesperson",
              "Supervisor / Foreman",
              "Manager / Executive"
            ],
            "type": "string"
          },
          "trade": {
            "description": "The trade performing the installation.",
            "enum": [
              "Electrical",
              "Plumbing",
              "HVAC",
              "Welding",
              "Carpentry",
              "Fire protection",
              "Concrete",
              "Roofing",
              "Gas fitting",
              "Solar / Battery"
            ],
            "type": "string"
          }
        },
        "required": [
          "trade",
          "region",
          "installation"
        ],
        "type": "object"
      },
      "name": "get_inspection_requirements"
    },
    {
      "description": "Lists all jurisdictions and regions supported by Legis-Link for a specific trade. Use this tool before calling other tools to confirm that the target region is supported, or to discover available regions when the user has not specified one. Returns a structured list of countries and their sub-regions (states, provinces, nations) along with the primary standards that apply in each region.",
      "inputSchema": {
        "properties": {
          "api_key": {
            "description": "Legis-Link API key. Optional: leave empty for the free tier (50 requests/day); Pro users paste their ll_p_ key.",
            "type": "string"
          },
          "trade": {
            "description": "The trade for which to list supported regions.",
            "enum": [
              "Electrical",
              "Plumbing",
              "HVAC",
              "Welding",
              "Carpentry",
              "Fire protection",
              "Concrete",
              "Roofing",
              "Gas fitting",
              "Solar / Battery"
            ],
            "type": "string"
          }
        },
        "required": [
          "trade"
        ],
        "type": "object"
      },
      "name": "list_supported_regions"
    },
    {
      "description": "[PRO] Checks whether a specific material, product, or component meets the code requirements for a given trade application and jurisdiction. Returns COMPLIANT, NON_COMPLIANT, or REQUIRES_VERIFICATION with the specific clause that governs the material selection, and — if non-compliant — the compliant alternative. Use this tool BEFORE ordering materials to avoid costly substitutions on site. Do NOT use this tool for general compliance questions — use check_compliance instead. Example inputs: '2.5mm2 TPS cable for 20A underground direct burial circuit NSW', 'Class 12 copper pipe for domestic hot water NSW', 'R3.5 glasswool batts for external wall cavity UK Building Regs'.",
      "inputSchema": {
        "properties": {
          "api_key": {
            "description": "Pro API key required.",
            "type": "string"
          },
          "material": {
            "description": "The material or product to check. Include: product name or type, specification or rating, and manufacturer if known. Example: '2.5mm2 TPS twin and earth, 450/750V rating, PVC insulation'.",
            "type": "string"
          },
          "region": {
            "description": "Use the state, province or country where the user works; if they have not said, ask them - never assume NSW or Australia. Jurisdiction. Determines which product standards and approval schemes apply.",
            "type": "string"
          },
          "role": {
            "default": "Qualified Tradesperson",
            "description": "Role of the person checking the material.",
            "enum": [
              "Apprentice / Trainee",
              "Qualified Tradesperson",
              "Supervisor / Foreman",
              "Manager / Executive"
            ],
            "type": "string"
          },
          "trade": {
            "description": "The trade context for this material check.",
            "enum": [
              "Electrical",
              "Plumbing",
              "HVAC",
              "Welding",
              "Carpentry",
              "Fire protection",
              "Concrete",
              "Roofing",
              "Gas fitting",
              "Solar / Battery"
            ],
            "type": "string"
          },
          "use_case": {
            "default": "standard installation",
            "description": "Where and how the material will be used. Include installation method, environmental conditions, load. Example: 'underground direct burial, 20A circuit, 30m run, clay soil'.",
            "type": "string"
          }
        },
        "required": [
          "trade",
          "region",
          "material"
        ],
        "type": "object"
      },
      "name": "verify_material_compliance"
    }
  ]
}

What the leaf hashes

{"body":"e3f2a1d472164d0898bd36b84941a9c5af2bc789b1dda97daec70b4ab68e334e","id":1226247,"kind":"mcp.tools","method":"probe.mcp/1","observed_us":1793332945281991,"prev":null,"subject":"95eddd47-f487-4191-a5bd-3756bb90e52d","subject_kind":"endpoint"}

Proof

Its day has not closed yet. A day closes ten minutes after midnight UTC; the proof appears here then.

How to check it · This row as JSON